Specifications

LTTR Calculator

Fastening Patterns

Certified Drainage Program (CDP) & Field Services

Case Studies


 


Typical Physical Properties* (Foam Portion)
PROPERTY

TEST METHOD

TYPICAL RESULTS
Dimensional Stability (Length and Width) ASTM D 2126 Less than 2 %
Compressive Strength (10% Deformation) ASTM D 1621 20 PSI
(138 kPa) or
25 PSI
(172 kPa)
Water Absorption ASTM C 209 ASTM D 2842 < 1 % < 3.5 %
Moisture Vapor Transmission ASTM E 96 < 1.0 perm (85.0ng/ (Pa•s•m2))
Product Density ASTM D 1622 Nominal 2.0 pcf (32.04 kg/m3)
Flame Spread ASTM E 84 (Full 10 min. Test) 40-60**
Smoke Developed ASTM E 84 (Full 10 min. Test) 50-170**
Tensile Strength ASTM D 1623 >730 psf (35 kPa)
Service Temperature - -40 to 200ºF

* The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. This data is offered as a service to our customers and is subject to change. All information can be confirmed by contacting Atlas’s Technical Department.

** The numerical ratings as determined by ASTM Test Method E 84 are not intended to reflect hazards presented by this or any other material under actual fire conditions. A flame spread index of 75 or less meets code requirements regarding flame spread for foam plastic roof insulation. However, flame spread values are not required for foam plastic insulation used in roof deck constructions that comply as an assembly with FM 4450 or UL 1256 (see IBC, BOCA, SBCCI, and ICBO model building codes, Chapter 26). Smoke Developed values do not apply to roofing.