Long-Term Thermal Resistance (LTTR)*
GEMINI PRE-CUT CRICKETS
MARKING
THICKNESS
SLOPE PER
AVERAGE
 
in
mm
foot
meter
LTTR Value
RSI
X
0.5"-1.0"
12-38
1/4"
6
6
1.06
Y
1.5"-2.5"
38-63
1/4"
6
12.1
2.13
Q
0.5"-2.5"
12-63
1/2"
12
9.0
1.58
2"
2.0"
50
N/A
N/A
12.1
2.13

* Long-term thermal resistance values were determined in accordance with CAN/ULC-S770. All test samples were third-party selected and tested by an accredited material testing laboratory. The R-value for .5 in. perlite (1.39) was provided by ASHRAE Handbook, Fundamentals. The R-value of .55 for 7/16 OSB was provided by APA-The Engineered Wood Association, which cited ASHRAE Handbook, Fundamentals. The R-value for .25 in. glass-mat gypsum board (.28 R-value) was provided by the glass-mat gypsum board manufacturer.